Barrier and permeation terms: a glossary for packaging engineers

Quick answer: this glossary is for packaging engineers, R&D and quality staff who need to read a technical data sheet or a lab report without a barrier specialist in the room. Use it to check which number you’re actually looking at, what test method produced it, and whether the conditions on the sheet match your product. Work through it top to bottom if you’re new to barrier testing, or jump to the term you’ve just seen on a data sheet.

Permeation: the thing all these terms describe

Permeation is the process by which a gas, vapour or liquid moves through a solid material without any hole or crack involved. Oxygen, water vapour, carbon dioxide, aroma compounds and mineral oil can all permeate a plastic film by dissolving into it on one side, diffusing through the polymer, and evaporating out the other side.

Every term below is a way of measuring or describing this diffusion process for one gas, through one material, under one set of conditions. Change the gas, the material or the conditions and the number changes, sometimes by orders of magnitude.

Barrier layer

A barrier layer is the specific layer in a multilayer film, laminate or bottle wall whose job is to slow permeation of a target gas or vapour. In a flexible pouch it’s often a thin EVOH or PVDC layer sandwiched between polyolefin layers that give sealability and strength. In rigid packs it might be a multilayer PET bottle wall, an internal coating, or a barrier added at the closure.

The barrier layer is rarely the thickest layer in the structure. A 7 micrometre EVOH layer can do more of the oxygen-blocking work than the 60 micrometre polyethylene layers either side of it. The laminate estimator gives an indicative barrier and weight for a layer stack, useful for a first check before you ask a converter for data.

OTR (oxygen transmission rate)

OTR is the rate at which oxygen gas passes through a given area of film or sheet, under steady-state conditions, usually expressed in cubic centimetres per square metre per day: cm3/(m2·day). It covers determination of the steady-state rate of transmission of oxygen gas through plastics in the form of film, sheeting, laminates, coextrusions, or plastic-coated papers or fabrics, and gives the oxygen gas transmission rate, permeance, and permeability coefficient.

The standard method is ASTM D3985, a coulometric sensor test. Oxygen permeability is typically measured at 23 °C and 0% relative humidity as per standard ASTM D3985. For packs that need to be checked in humid conditions, in moist conditions, for example at 38 °C and 90% relative humidity, standard ASTM F1927 is used. ISO 15105-2 is the equivalent international standard. Always read the temperature and humidity next to the OTR number; a film’s oxygen barrier can shift a great deal between dry and humid conditions, especially for hydrophilic materials like EVOH.

WVTR (water vapour transmission rate)

WVTR measures how much water vapour passes through a given area of material in a given time, expressed in grams per square metre per day: g/(m2·day). It’s determined according to the ASTM F1249 standard and describes the amount of water vapour that passes through a material over a set period. The modulated infrared sensor method behind ASTM F1249 compares a dry chamber to a humid chamber separated by the test material.

An accepted unit of WVTR is g/(m2·day), and the test conditions of relative humidity and temperature, where the humidity is the difference in relative humidity across the specimens, must be stated. A common test point for food packaging is 38 °C and 90% relative humidity on one side, close to dry on the other. Always check which conditions are quoted: a WVTR at 23 °C/50% RH is not comparable to one at 38 °C/90% RH.

MVTR (moisture vapour transmission rate)

MVTR is the same measurement as WVTR under a different name. The two terms are used interchangeably across the packaging, textile and building industries, and both refer to the mass of water vapour crossing unit area in unit time. You’ll see WVTR more often on plastic film and laminate data sheets and MVTR more often in textile, nonwoven and construction contexts, but they describe the identical physical quantity and usually the same family of standard test methods, including ASTM F1249 and the older gravimetric ASTM E96.

If a data sheet quotes MVTR instead of WVTR, treat it exactly the same way: check the temperature, the relative humidity difference, and which test method produced the figure before comparing it with anything else.

CO2TR (carbon dioxide transmission rate)

CO2TR measures carbon dioxide permeation through a material, in the same cm3/(m2·day) units as OTR. It matters most for carbonated drinks and some modified-atmosphere packs, where CO2 loss or ingress changes carbonation level or shelf life. Carbon dioxide transmission rates are commonly measured according to ASTM F-2476 at 23 °C, 0% relative humidity, and 1 atmosphere of pressure. CO2 generally permeates most plastics faster than oxygen does, so a film’s CO2 barrier is usually weaker than its O2 barrier, not stronger.

Permeance

Permeance is the transmission rate normalised for the pressure or concentration difference driving the permeation, but not for thickness. An accepted unit of permeance is the metric perm, or g/(m2·day·mmHg), while the SI unit is mol/(m2·s·Pa). It’s a property of a specific sample at a specific thickness, not a material constant.

Permeance lets you compare two samples tested under different pressure gradients. It does not let you compare samples of different thickness on a fair basis; for that you need the permeability coefficient.

Permeability coefficient

The permeability coefficient is the permeance multiplied by thickness, which makes it (in principle) a property of the material itself rather than of one particular sample. Water vapour permeability coefficient is the product of the permeance and the thickness of the film. Typical units are cm3·mm/(m2·day·atm) for gases, or the barrer in academic literature.

Published research on EVOH illustrates why this matters: the oxygen permeability coefficient of EVOH containing 32 mol% ethylene, measured at 20 °C and 65% relative humidity according to ISO 14663-2, was reported as 6 cm3·mm/(m2·day·atm), far below the figure for plain PET. Because it’s normalised for thickness, the permeability coefficient is the right number to use when comparing a 12 micrometre EVOH layer against a 25 micrometre one. The unit converter helps when a data sheet quotes permeability or thickness in units you don’t normally use.

Test conditions: why temperature and RH are not optional details

Every OTR, WVTR, MVTR or CO2TR figure is only valid for the temperature, relative humidity and gas concentration it was measured at. ASTM D3985 is typically run dry, at 23 °C; ASTM F1249 is typically run at a fixed temperature with a humidity gradient, often with the wet side at 90% RH. Moving from dry to humid conditions can change OTR by a large margin for moisture-sensitive barrier polymers.

When you ask a supplier for a barrier figure, ask for the standard, the temperature and the relative humidity on both sides of the sample, not just the headline number. A film rated “excellent oxygen barrier” with no conditions attached tells you almost nothing.

EVOH

EVOH (ethylene vinyl alcohol copolymer) is a widely used oxygen-barrier resin, usually coextruded as a thin inner layer in multilayer film or bottles because it cannot be heat-sealed or exposed to moisture on its own. A typical EVOH film with 32% ethylene content achieves an OTR of around 0.3 cm3/(m2·day) at 23 °C and 65% relative humidity, roughly 100 times lower than PET. Its oxygen barrier weakens as it absorbs moisture, which is why it’s always laminated between moisture-resistant layers rather than used alone.

PVDC

PVDC (polyvinylidene chloride) is a coating or coextruded layer used for both oxygen and moisture barrier, common on cling film, some meat and cheese packaging, and certain blister formats. Unlike EVOH, its barrier performance is far less sensitive to humidity, which makes it a common choice where a pack needs a stable barrier across a wide range of storage conditions. PVDC has come under environmental and regulatory pressure in some markets because of its chlorine content and recycling incompatibility; check current guidance before specifying it.

Metallised film (VMPET, VMCPP)

Metallised film has a very thin layer of vacuum-deposited aluminium, typically tens of nanometres thick, applied to PET or CPP film. Providing a gauzy aluminium layer to the plastic film can reduce the oxygen transmission rate by a factor of up to 100 and also provides light protection. Typical figures reported for metallised PET (VMPET) run around 0.5 to 2.0 cm3/(m2·day) for OTR and 0.3 to 1.0 g/(m2·day) for WVTR, well below plain PET or BOPP but still not as tight as solid aluminium foil.

Foil itself remains the reference point: aluminium foil typically has an OTR below 0.1 cm3/(m2·day) and shows no sensitivity to ambient humidity. The trade-off is that both metallised film and foil laminates are opaque or near-opaque, and current recycling streams generally cannot separate the aluminium from the plastic carrier, which matters under extended producer responsibility and recyclability rules; see ppwreu.org for the current text.

Transparent oxide coating (SiOx, AlOx)

SiOx (silicon oxide) and AlOx (aluminium oxide) are thin, transparent ceramic-like coatings deposited on film by vacuum or plasma processes, used where a pack needs barrier performance but also needs to stay see-through or microwavable. Vapour deposition of SiOx has the potential to reduce permeation by approximately 100 times, and SiOx and AlOx coatings on polyolefin films can reduce the oxygen transmission rate by approximately 90%. Reported OTR for AlOx or SiOx-coated PET typically sits in the 0.5 to 2.0 cm3/(m2·day) range, while remaining microwave compatible, broadly similar to metallised PET but without the opacity.

Multilayer and coextruded barrier structures

Most real barrier packs are not single materials but stacks: an outer layer for printing and stiffness, a barrier layer (EVOH, PVDC, foil or a coating), and an inner sealant layer compatible with the product. The overall OTR or WVTR of the stack depends on every layer, the adhesive or tie layers between them, and how well they’re bonded, not just on the barrier layer in isolation.

Comparative figures on BOPP/metallised-BOPP versus barrier-adhesive laminates show the difference a construction choice makes: typical BOPP has a water vapour transmission rate of 3 to 6 g/(m2·day) at 38 °C and 90% relative humidity, and an oxygen transmission rate typically in the range of 1,500 to 2,500 cm3/(m2·day) at 23 °C and 0% relative humidity, far weaker on oxygen than a laminate that adds EVOH or metallisation. Plain PET sits in between: PET typically shows an OTR of 50 to 130 cm3/(m2·day) at 23 °C, 0% RH, but a more moderate WVTR of 15 to 25 g/(m2·day) at 38 °C, 90% RH, the reverse barrier profile to BOPP.

Typical oxygen transmission rate by material
Typical oxygen transmission rate by material
Typical water vapour transmission rate by material
Typical water vapour transmission rate by material

High barrier laminate (foil lamination)

A high barrier laminate adds a full aluminium foil layer, usually 6.5 to 9 micrometres thick, rather than a metallised or coated layer. In order of barrier strength, the usual choices run from aluminium foil, through metallised PET or CPP, transparent AlOx or SiOx-coated PET, EVOH film, to PVDC coatings. Foil laminates give the lowest permeation of any common flexible structure and are standard for products needing long ambient shelf life with no light or oxygen ingress, such as retort pouches and some pharmaceutical strip packs. The cost is opacity, inability to go through a metal detector, and poor recyclability in mixed-material form.

Reading a barrier data sheet: a quick comparison

Term What it measures Typical standard Typical unit
OTR Oxygen transmission ASTM D3985 / ISO 15105-2 cm3/(m2·day)
WVTR / MVTR Water vapour transmission ASTM F1249 / ISO 15106-2 g/(m2·day)
CO2TR Carbon dioxide transmission ASTM F2476 cm3/(m2·day)
Permeance Transmission per unit pressure gradient, sample-specific Derived from the above g/(m2·day·mmHg)
Permeability coefficient Permeance normalised by thickness Derived from the above cm3·mm/(m2·day·atm)

What this means for you

When a supplier sends a barrier number, ask three things before you use it: which standard produced it, what temperature and relative humidity it was measured at, and whether it’s a transmission rate (sample-specific) or a permeability coefficient (thickness-normalised). Two films with the same quoted OTR but different test conditions are not comparable, and a thinner film with a “better” OTR might have a worse permeability coefficient.

Match the barrier type to the risk: oxygen-sensitive products need low OTR under conditions close to the pack’s real storage humidity, moisture-sensitive products need low WVTR at a realistic temperature, and carbonated products need the CO2TR checked as well, since it’s rarely quoted by default. If recyclability matters for the pack, remember that the tightest barriers (foil, PVDC) are usually the hardest to recycle, so check the current PPWR text at ppwreu.org before locking in a structure. For a first estimate of how a layer stack performs before you get lab data back, the laminate estimator and the material properties table are useful starting points, and the fill headspace calculator helps when headspace oxygen, not just pack permeation, is driving your shelf life calculation.

Sources

Values are typical figures from the cited sources. Real performance depends on the grade, the test method and the conditions. Check the supplier's data sheet and test your own structure.